Kick Tolerance for iPad, release 2.2, now available on the iTunes App Store
Kick Tolerance for iPad, release 2.2

The Kick Tolerance provides to drilling engineers, chemists, technicians, students and others professionals in the Oil & Gas industry a productivity tool helpful in drilling operation (well control) and planning phase of oil wells.
This version is completely interactive and allows users to define a wide variety of parameters for oil wells, save data to files.
This application deals with two concepts:
1- Kick Tolerance as Maximum Pore Equivalent Weight;
2- Kick Tolerance as Maximum Kick Volume.
Both with graphical analyzes.
For both the concepts, the calculations uses the Fracture Gradient defined in “Well Configuration -> Gradients” views.
1. For KT as Maximum Pore Equiv Weight
– Plot KT x Maximum Kick Volume
KT (Maximum Pore Equiv Weight) = mudWeight + (casingShoe/wellDepth) * (Fract Equiv Weight – mudWeight) – (KickLength/wellDepth) * (mudWeight – kickDensity);
=> Known the Maximum Kick Volume, find the KT as the Maximum Pore Gradient;
2. For KT as Maximum Pit Gain Volume:
Plot KI = the difference ( Pore Equiv Weight – Mud Weight ) versus Maximum Kick Volume (Pit Gain)
KI (Pore Equiv Weight – Mud Weight)
= (casingShoe/wellDepth) * (Fract Equiv Weight – mudWeight) – (KickLength/wellDepth) * (mudWeight – kickDensity);
=> Known the difference (Pore Equiv Weight – Mud Weight), find the Kick Tolerance as Maximum Kick Volume.
Calculation of the Kick Tolerance by this App:
1. Hmax below the casing shoe = (MaxSICP – SIDPP) / (0.052 x (ρmud-ρkick));
– MaxSICP = 0.052 x (ρfracture – ρmud) x CasingShoeTVD
– SIDPP = 0.052 x KI x Well TVD
2. Calculate V1 = Maximum Volume annulus bellow the casing shoe;
3. Calculate V2 at bottom = (V1 x Pfracture) / Ppore;
4. Calculate V3 = Volume annulus at bottom using Hmax;
The kick tolerance is the smaller of the two volumes between V2 and V3.
This KT is showed in the Graph: KI versus KT Volume.
| |
| |
| |